Green solenoid valve for Junkers WR11 87085012500 water heater burners
Green solenoid valve Junkers burners
Green solenoid valve for Junkers water heater burners. Coil opens/closes burners
Pay close attention to this model of Junkers. This solenoid valve only controls burners and does not have the outlet for threading the pilot tube.
If your water heater screws the pilot tube into the green valve, and your water heater does not have an orange valve, the valve you should install is:
Please check the "COMPATIBLE MODELS" tabs below
If your heater sparks, ignites the pilot light but doesn't ignite or ignites very little, it is very likely that this valve is faulty.
We recommend checking the flame detector and verifying with a multimeter if the valve is receiving power to rule out other possible electrical faults. If the flame detector in the Junkers water heater is faulty, it will not allow current to flow to open this valve
It is possible that the faston terminal of your valve matches the other side to connect the cable coming from the electronic module, don't worry, the cable reaches perfectly, just connect it.
Remember that if it ignites very little, it may be the gas pressure; check the cylinder head or the gas supply.
Green solenoid valve for Junkers gas heater burners. Compatible with Junkers and Neckar models.














Ratings
There are no reviews yet